Call UsCall Us : 07313726683
Low Energy Trip Assembly
Low Energy Trip Assembly

Low Energy Trip Assembly

MOQ : 100 Pieces

Low Energy Trip Assembly Specification

  • Machine Type
  • Circuit Breaker Accessory
  • Magnet Grade
  • Premium
  • Magnet Category
  • Electromagnetic Trip
  • Thickness
  • Standard (varies per model)
  • Composite
  • Metal-Polymer Composite
  • Shape
  • Rectangular Assembly
  • Application
  • Low voltage circuit breakers, Electrical panels, Industrial control equipment
  • Size
  • Compact (custom models available)
  • Weight
  • Lightweight (depends on specification)
  • Color
  • Grey / Metallic
  • Function
  • Facilitates low energy tripping in circuit breakers
  • Brand Required
  • Customizable / As per requirement
  • Capacity
  • Low Energy
  • Material
  • Copper and Insulated Polymer
  • Assembly Type
  • Factory assembled and tested
  • Contact Material
  • Silver alloy contacts
  • Conformance Standards
  • IS/IEC 60947-2
  • Response Time
  • <10 ms
  • Storage Condition
  • Dry and Dust-free environment
  • Insulation Resistance
  • >1000 M at 500V DC
  • Operating Voltage
  • 220-240V AC/DC
  • Mounting Type
  • Panel or Base Mount
  • Service Life
  • >10,000 Operations
  • Trip Current Range
  • Low energy threshold (precisely calibrated)
  • Temperature Range
  • -10C to +55C
 

Low Energy Trip Assembly Trade Information

  • Minimum Order Quantity
  • 100 Pieces
  • Payment Terms
  • Cash Advance (CA)
  • Delivery Time
  • 10 Days
  • Main Domestic Market
  • All India
 

About Low Energy Trip Assembly

We are providing an extensive range of Low Energy Trip Assembly. It is design to protect an electrical circuit from any further damage. It is made with a heavy duty steel frame to give a solid strength and tolerate other heat pressure. This range is able wot allow maximum safety for the operator. Low Energy Trip Assembly is easy to adjust the trip current of the device after assembly. It requires less repairing and maintenance due to its advance technology of tools.

 

 



Efficient Low Energy Tripping

Designed for high sensitivity, this assembly ensures that even minimal fault currents are rapidly and accurately detected, facilitating swift interruption to protect equipment and personnel. The precise calibration guarantees dependable operation within low energy parameters, preventing unnecessary downtime or system damage.


Robust Construction & Premium Materials

Built using metal-polymer composite and high-grade copper, the assembly blends durability with advanced insulation. Silver alloy contacts enhance conductivity and longevity, while the assembly's compact, rectangular design is adaptable to most panel or base mount configurations.


Compliance & Reliability

Fully compliant with IS/IEC 60947-2 standards, the device is factory-tested for insulation resistance and rapid response. It boasts a long service life exceeding 10,000 operations, ideal for demanding industrial or commercial environments.

FAQ's of Low Energy Trip Assembly:


Q: How is the Low Energy Trip Assembly installed in circuit breaker systems?

A: The assembly is designed for easy panel or base mounting within circuit breaker compartments or electrical panels. Detailed installation guidelines are provided to ensure correct positioning and secure connections.

Q: What process ensures the assembly's precise calibration and reliability?

A: Each unit is factory assembled and tested, guaranteeing calibrated low-energy trip current thresholds, insulation resistance above 1000 M, and response times under 10 ms for consistent, reliable operation.

Q: Where is this trip assembly typically used?

A: It is commonly utilized in low voltage circuit breakers, electrical distribution panels, and industrial control equipment, especially where precise low-energy tripping is crucial for system protection.

Q: When should a Low Energy Trip Assembly be chosen over standard trip units?

A: Choose this assembly when equipment protection at minimal fault currents or enhanced sensitivity is required, such as in sensitive industrial, commercial, or critical power installations.

Q: What benefits does this assembly provide to end-users and maintenance teams?

A: End-users benefit from reliable, quick-response tripping that helps prevent equipment damage and reduces system downtime. Maintenance teams appreciate its robust service life and straightforward integration.

Q: How does the customizable brand option work for manufacturers and suppliers in India?

A: Manufacturers and suppliers can request assemblies tailored to their branding or technical requirements, ensuring compatibility with a wide assortment of circuit breaker models and applications.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Electromagentic Assembly Category

Industrial Electromagnetic Assembly

Industrial Electromagnetic Assembly

Price Range 300.00 - 1000.00 INR / Piece

Minimum Order Quantity : 100 Pieces

Shape : Other, Rectangular

Size : 300 mm x 200 mm x 75 mm

Function : Electromagnetic Lifting & Separation

Capacity : Up to 200 Kg

High Power Electromagnetic Assembly

High Power Electromagnetic Assembly

Price Range 300.00 - 1000.00 INR / Piece

Minimum Order Quantity : 100 Pieces

Shape : Other, Rectangular Module

Size : 200 mm x 120 mm x 25 mm

Function : Electromagnetic field generation for lifting and separation

Capacity : High Power

Trip Coil Assembly

Trip Coil Assembly

Minimum Order Quantity : 100 Pieces

Shape : Other, Cylindrical with mounting bracket

Size : 75 mm length x 30 mm diameter

Function : Instantaneous tripping mechanism for breakers

Capacity : Suitable for standard breaker coils, up to 250V operation

RMU Series Trip Assembly

RMU Series Trip Assembly

Price Range 300.00 - 1000.00 INR / Piece

Minimum Order Quantity : 100 Pieces

Shape : Other, Rectangular / Modular Assembly

Size : Standard/Customized (based on RMU model)

Function : Trips the circuit in abnormal/fault conditions

Capacity : Suitable for Medium Voltage (MV) RMU applications